NDT Ops

CorrosionRADAR

CR:LR long-range CUI sensors (corrosion and moisture) with IoT CR Node

Request a quote Source: corrosionradar.com

Source: corrosionradar.com (accessed 2026-10-16). Confirm specifications with the manufacturer before ordering.

Specifications

Vendor
CorrosionRADAR
Brand / line
CR:LR
Category
Guided wave and CUI
Class
Core integrity
Technique
Electromagnetic guided radar (EMGR) sensing cable under insulation, corrosion and moisture sensor types
Detects
moisture/CUIcorrosion rate
Mounting
Installed on asset surface beneath insulation (linear or helical), requires insulation removal at install; modular up to 100 m, 50 m per node channel
Temperature range
-90 to 260 °C
Communications
LoRaWANBluetoothCellularEthernet
Power
Node battery 6 V, 5-7 years depending on acquisition cycle
Hazardous area
ATEX/IECEx: node Zone 2, sensor connections Zone 1 (Ex ic [ib Gb] IIB T4 Gc)
Suitable assets
pipingpressure vesselsstorage tanksheat exchangers
Notes
Data goes to CR:CLARITY cloud/on-prem dashboard (LoRaWAN to gateway, gateway via cellular or Ethernet). Datasheet claims inspection cost reduction up to 65% (vendor claim). Datasheet July 2026.

Related in Guided wave and CUI