NDT Ops

Cosasco

Retrievable Flush Element ER Probe 4705

Request a quote Source: cosasco.com

Source: cosasco.com (accessed 2026-10-16). Confirm specifications with the manufacturer before ordering.

Specifications

Vendor
Cosasco
Category
Corrosion probes
Class
Core integrity
Technique
Electrical resistance (ER), flush element
Detects
wall losscorrosion rateerosion
Mounting
Retrievable via high-pressure access fitting; flush mounted
Temperature range
Max +260 °C
Communications
Wired (other)
Suitable assets
pipingpressure vesselspipelines
Notes
Max 6000 psi; 316L body.

Related in Corrosion probes