Specifications

Vendor
Honeywell
Brand / line
SmartCET (InterCorr)
Category
Corrosion probes
Class
Core integrity
Technique
LFI (low-frequency impedance, LPR variant) + harmonic distortion analysis + electrochemical noise; outputs general corrosion rate, pitting factor, B value, CMI
Detects
corrosion ratewall loss
Mounting
Intrusive 3-electrode probe with transmitter
Communications
4-20 mA/HART
Power
2-wire loop
Hazardous area
ATEX Ex ia Zone 0/1; CSA Class I Zone 0 Ex ia
Suitable assets
pipingpressure vesselsheat exchangers
Notes
Honeywell Product Information Note (hosted on Yodify library, which is Honeywell's PIN distribution). Not on process.honeywell.com in this fetch (page 404). Type 4X/IP66/67 housing, local display, galvanic isolation.