NDT Ops

AMETEK

EXSH1 EX LWIR (LWIR-640 in flameproof housing)

Request a quote Source: ametek-land.com

Source: ametek-land.com (accessed 2026-10-16). Confirm specifications with the manufacturer before ordering.

Specifications

Vendor
AMETEK
Brand / line
AMETEK Land
Category
Thermal and furnace
Class
Adjacent
Technique
LWIR-640 thermal imager (8 to 14 µm, 640x480) in Ex d flameproof stainless housing with germanium window
Detects
temperaturehot spots
Mounting
Fixed, 316/316L stainless steel housing, no purge air required, gridless window, optional air or water cooling
Temperature range
LWIR-640 ranges: -20 to 120, 0 to 500, 100 to 1000 °C; housing ambient -40 to +70 °C certified (to +160 °C Zone 2/22 with water cooling)
Communications
Ethernet
Power
19 to 26.4 Vdc, 2.3 A max
Hazardous area
ATEX/IECEx/UKEX Zones 1/21: II 2 (1) G D Ex db [op is Ga] IIC T6 Gb; Zones 2/22: II 3 (1) G D Ex db ... Gc; IP66/IP68
Suitable assets
furnace/heater tubesrefractoryflarepressure vessels
Notes
Weight 20 kg max; Ø168 x 356 mm.

Related in Thermal and furnace

AMETEK

LWIR-640

Long-wave infrared (8 to 14 µm) radiometric thermal imager, 640x480, up to 60 Hz, integrated web server

temperaturehot spots

Ethernet

Details for LWIR-640 →