NDT Ops

MISTRAS Group

CALIPERAY Remote Thickness Tracker

Request a quote Source: caliperay.com

Source: caliperay.com (accessed 2026-10-16). Confirm specifications with the manufacturer before ordering.

Specifications

Vendor
MISTRAS Group
Brand / line
CALIPERAY
Category
Permanently installed UT
Class
Core integrity
Technique
Ultrasonic (permanently mounted single/dual crystal transducers)
Detects
wall losscorrosion rateerosion
Mounting
Permanently mounted on piping and vessel walls; wireless mesh
Temperature range
Transducers -55 to 350 C (single crystal ISSUT5M-HT); dual crystal -55 to 150 C
Communications
WirelessHART
Power
Battery-powered wireless nodes (lithium D per Ionix systems datasheet; not stated on MISTRAS page)
Hazardous area
IS Class I Div 1 Groups A-D; Ex ia IIC T4 Zone 0; ATEX FM15ATEX0043X
Suitable assets
pipingpressure vessels
Notes
Resolution about 2 mil. Web app, PCMS/IDMS export. Page copyright 2017; Ionix systems datasheet indicates HotSense probes powering Caliperay.

Related in Permanently installed UT